Inline Electrochemistry Analyzers
Instruments and electrodes used to provide ongoing or production-related parameter measurements for water and solutions; sensors or electrodes are incorporated into the inflow or outflow to maintain quality or assess changes in real time.
Temperature (Metric) Operating
- (2)
- (1)
Type
- (1)
- (1)
- (1)
Filtered Search Results
Products from some of our suppliers do not display in filtered search results. Please
clear all filters
to see these products.
1
–
2
of
2
results
Thermo Scientific™ Orion™ 2110XP Ammonia Analyzer
Control and optimize boiler ammonia levels with continuous, direct and precise ammonia measurements from the Thermo Scientific™ Orion™ 2110XP Ammonia Analyzer.
| Enclosure Rating | Waterproof; IP66; NEMA 4X |
|---|---|
| Width (English) | 17 in. |
| Length (Metric) | 27 cm |
| Response Time | 95% within 2 minutes of injecting a standard solution |
| Length (English) | 11 in. |
| Width (Metric) | 45 cm |
| Channels | 1 |
| Channel1 | Ammonia |
| Sample Streams | 1 |
| Includes | 2110XP ammonia analyzer with Ammonia electrode, reference electrode (100056), ATC probe (2100TP),ammonia calibration standards kit, CD user guide and options kit |
| Channel2 | Optional ph/ORP or Conductivity |
| Flow Rate | 40mL/min. |
| Accuracy | ±15% or 30 ppb, whichever is greater |
| Mounting Options | Wall mount |
| Display Type | Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts |
| Voltage | 85/132 VAC, 170/264 VAC |
| Amperage | 5A |
| Resolution (mV) | 0.1mV |
| Inlet Pressure | 8 to 100psig |
| Certifications/Compliance | CE, CSA, UL, FCC Class A limits |
| Analog Outputs | 2, Galvanically Isolated |
| Case Material | Valox 364 |
| Accuracy (Temperature) | ±0.5°C |
| Relay Details | 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A |
| Height (English) | 26 in. |
| Height (Metric) | 65 cm |
| Communication Details | Modbus with Additional Module |
| Accuracy (mV) | ± (0.5 mV + 0.1%) |
| Keypad Type | Membrane |
| Measurement Ranges | 0 to 10ppm |
| Calibration | Double Known Addition |
| Sample Temperature | 5 to 45°C |
| Current Loops | 2 |
| Alarm Output | 3 |
| Dimensions (L x W x H) | 11 x 17 x 26 in. (27 x 45 x 65cm) |
| Max. Relative Humidity | 5 to 95%, non-condensing |
| Outputs | 0 to 20 mA; 4 to 20 mA |
| Frequency | 0 to 60 Hz |
| Resolution (Temperature) | 0.1°C |
| Range (mV) | ±1999.9m |
| Temperature (Metric) Operating | 5°C to 35°C |
| Sample Inlet | 1/4 in. NPTF tube fitting |
Thermo Scientific™ Consumables and Services Kits for Orion™ 2110XP Ammonia Analyzer
Keep needed supplies and service items in stock to avoid lost productivity with Thermo Scientific™ Consumables and Services Kits for Orion™ 2110XP Ammonia Analyzer.