Thermo Scientific™ Hypersil™ CPS-2 Cyano (CN) Mixed Mode HPLC Column, 5 μm, 4 mm x 150 mm

Product Code. 10393605 Shop All Thermo Scientific Products
Change view
Click to view available options
Length (Metric):
150 mm
Packungsgröße:
Each
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Artikelnummer. Length (Metric) unitSize
10393605 150 mm Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Dieser Artikel kann nicht zurückgegeben werden. Rückgaberichtlinie anzeigen
Artikelnummer. 10393605 Lieferant Thermo Scientific™ Lieferanten-Nr. 31805154030

This item has been discontinued and is no longer available. View the product for possible alternatives or contact our Technical Support team on +351 21 425 33 50 for assistance
Alternative Produkte anzeigen

Dieser Artikel kann nicht zurückgegeben werden. Rückgaberichtlinie anzeigen

Carbon Load: 4%; Pore Size: 120 Å; Column Phase: Reversed Phase and Normal Phase

A cyanopropyl phase for both normal and reversed phase HPLC

  • Operates in both normal and reversed phase modes
  • More rapid mobile phase equilibration compared with silica in normal phase
  • Not deactivated by traces of water in normal phase
  • When used as a reversed phase material, cyano selectivity complements the alkyl chain bonded phases, but with lower hydrophobicity
  • One of the least retentive of reversed phase materials and, therefore, useful to separate polar compounds

Bestellinformation

Other column dimensions are also available. Please call Customer Service for more information.

TRUSTED_SUSTAINABILITY

Spezifikation

Diameter (Metric) 4 mm
Length (Metric) 150 mm
Particle Size 5 μm
Pore Size 120 Å
Surface Area 170 m²/g
USP Type L10
Stationary Phase Cyano (CN)
Packing Material Silica
Carbon Load 4%
Column Type Mixed Mode
Endcapped Yes
Phase Normal and Reversed Phase
Mehr anzeigen Weniger anzeigen
Name des Produkts
Wählen Sie ein Thema

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.