Thermo Scientific™ Orion Star™ A222 Conductivity Portable Meter
Reliably measure conductivity, TDS, salinity, resistivity and temperature with the Thermo Scientific™ Orion™ Star A222 Conductivity Portable Meter for advanced field analysis
619.00€ - 965.00€
Specifications
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
|---|---|
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Product Code | Brand | Description | Includes | Price | Quantity & Availability | ||||
|---|---|---|---|---|---|---|---|---|---|
| Product Code | Brand | Description | Includes | Price | Quantity & Availability | ||||
| 11651469 |
Thermo Scientific™
STARA2220 |
Orion Star A222 conductivity/TDS/salinity/resistivity portable meter | Star A222 conductivity meter, 4 AA batteries, literature CD, printed quick start guide, computer interface cable and meter test certificate |
619.00€ Each |
|
11661469 |
Thermo Scientific™
STARA2225 |
Orion Star A222 conductivity/TDS/salinity/resistivity portable meter kit with DuraProbe 4-cell conductivity sensor, solutions, meter armor and field case | Star A222 Conductivity Meter with Batteries; 013010MD DuraProbe Epoxy 4-Probe (K=0.475) Conductivity Probe with 3 Meter Cable; 01100710 Conductivity 1413uS Standard Pouches; 911110 Rinse Solution Pouches; STARA-CS Star A Meter Hard Carrying Case; STARA-AR Protective Armor with Electrode Holder |
965.00€ Each |
|
Description
Don’t leave your measurements to chance when analyzing samples outside the lab. Orion Star A222 conductivity portable meters are designed to offer the reliability you need in a user-friendly package for your dedicated conductivity testing needs. This waterproof portable meter displays critical data with your measurement including temperature, date and time, read type, measurement stability, active calibration info and power source status.
- Measure conductivity, TDS, salinity or resistivity with temperature
- Perform up to a five point conductivity calibration
- Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate
- Use linear, non-linear or off conductivity temperature compensation with 15, 20 or 25°C reference temperatures
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Capture your critical readings with measurement stability indicator and selectable read modes – Auto-Read holds a stable reading and Continuous shows changing readings with hold option
- Data log collects and date/time stamps up to 1000 measurement sets
- Non-volatile meter memory ensures your data and settings are protected, even with loss of power
- Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
- Flexible power options with AA batteries or universal power adapter
- IP67-rated housing is waterproof for rugged field operation
- Meter kits include hard-sided field case and protective meter armor with electrode holders, adjustable wrist/belt strap and built-in meter stand
- Meters offer CE, TUV 3-in-1 and FCC Class A certifications and 3-year replacement warranty
Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.
Specifications
| Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) | |
| 0.5% of reading ±1 digit | |
| 0.5% of reading ±1 digit | |
| Calibration due alarm (fixed 12 hour) | |
| 800 hours | |
| Conductivity and temperature | |
| CE, TUV 3-1, FCC Class A | |
| 2-cell or 4-cell conductivity sensors with built-in temperature | |
| Up to 5 | |
| Graphic LCD with backlight | |
| IP-67 | |
| Automatic data logging with Auto-Read measure mode; manual data logging with Continuous measure mode | |
| 0.001 µS/cm to 3000 mS/cm | |
| 0.06 to 80.00 psu, 0.05 to 42.00 ppt | |
| 8 pin MiniDIN (conductivity sensor with built-in temperature) | |
| Conductivity, TDS, salinity or resistivity with temperature | |
| 10 per channel with password protection | |
| 4 AA batteries (included) or universal AC adapter (sold separately) | |
| 5 to 85 %, non-condensing | |
| 1 ohm or 0.1 meg-ohm, auto ranging | |
| 0.001 ppm minimum, auto ranging up to 4 significant digits | |
| Practical salinity (psu) | |
| Linear (0.02 to 9.99) | |
| 1 point temperature offset calibration | |
| 3 year meter warranty |
| 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS | |
| 0.5% of reading ±1 digit | |
| ±0.1°C | |
| Yes, selectable | |
| Four AA (included) | |
| 0.001 to 199.9cm-1 | |
| 1 | |
| Transfer single, range or all data points to printer or computer | |
| 1000 with date and time stamp | |
| 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) | |
| English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update | |
| USB, RS232 | |
| 2 ohm to 100.0 meg-ohm | |
| 0.001 to 200.0 ppm | |
| Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys | |
| Non-volatile memory preserves data log, calibration log and meter settings | |
| Orion Star A222 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter | |
| -5.0° to 105.0° C, 22.0° to 221.0° F | |
| 0.001 μS minimum, auto ranging up to 4 significant digits | |
| 0.01 psu or 0.01 ppt minimum, auto ranging | |
| 0.1°C, 0.1°F | |
| Smart Stability and Smart Averaging | |
| Linear, nLFn (non-linear ultra pure water) or off | |
| Manual or automatic with ATC temperature probe | |
| 0.5kg |