Aalborg™ Digital Mass Flowmeter

Product Code. 11707629
Change view
Click to view available options
Airflow Rate:
0 to 10 mL/min.
20 to 50 L/min.
Model:
Digital Mass Flowmeter
Stainless Steel Mass Flowmeter
Total Air Mass Flowmeter
Unit Size:
Each
4 product options available for selection
Product selection table with 4 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Airflow Rate Model unitSize
11707629 0 to 10 mL/min. Total Air Mass Flowmeter Each
13507360 20 to 50 L/min. Digital Mass Flowmeter Each
11727629 0 to 10 mL/min. Digital Mass Flowmeter Each
15359904 0 to 10 mL/min. Stainless Steel Mass Flowmeter Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 4 options available.
4 options
This item is not returnable. View return policy
Product Code. 11707629 Supplier Aalborg™ Supplier No. DFM26SVAL2AA5/3AB01SS

Please to purchase this item. Need a web account? Register with us today!

This item is not returnable. View return policy

Use a local four button teypad and LCD to access all features of the flow meter. Aalborg™ Digital Mass Flowmeter supports automatic sensor zero offset adjustments.

  • Flow Alarm
    • High and Low gas flow ALARM limits can be preprogrammed via keypad or remotely via digital interface. ALARM conditions become true when the current flow reading is equal or higher/lower than corresponding values of high and low alarm levels. Alarm action can be assigned with preset delay interval (0-3600 seconds) to activate the contact closer (separate for High and Low alarm).
  • Pressure Alarm
    • High and Low gas pressure ALARM limits can be preprogrammed via keypad or remotely via digital interface. Pressure alarm conditions become true when the current pressure reading is equal or higher than corresponding values of high pressure alarm settings or equal or lower than corresponding values of low pressure alarm settings. Alarm action can be assigned to activate the contact closer (separate for High and Low pressure alarm).
  • Temperature Alarm
    • High and Low gas temperature ALARM limits can be preprogrammed via keypad or remotely via digital interface. Temperature alarm conditions become true when the current temperature reading is equal or higher than corresponding values of high temperature alarm settings or equal or lower than corresponding values of low temperature alarm settings. Alarm action can be assigned to activate the contact closer (separate for High and Low temperature alarm).
  • Engineering Units
    • The flow set points, measured gas flow and associated totalizer data are scaled directly in engineering units via the front panel keypad or digital interface.

Certifications

NIST

Specifications

Type Flowmeter
Accuracy ±1%
Airflow Rate 0 to 10 mL/min.
Pressure Rating 5 to 100 psig
Certifications/Compliance NIST calibration certificate
Connections 0.63 cm (0.25 in.) Standard Compression Fittings
Flow Rate Range 0 to 10 mL/min.
Height (Metric) 165 mm
Model Total Air Mass Flowmeter
Power Supply Details 12VDC
Repeatability ±0.15% (Full Scale)
Scale Full scale
Temperature (Metric) 5°C to 50°C