Products designed for use during real-time (quantitative) PCR procedures. Includes master mixes, DNA polymerases, reverse transcriptases, size standards, kits, and reagents.
Reverse transcription polymerase chain reaction (RT-PCR) is a laboratory technique that combines the reverse transcription of RNA into DNA and the subsequent amplification of the DNA using PCR.
In RT-PCR, a reverse transcriptase enzyme converts an RNA template to its complementary DNA (cDNA). The cDNA then becomes the template for PCR amplification.
A typical RT-PCR kit includes the main components needed for the assay:
- Buffer
- Primers – a combination of deoxynucleotide triphosphates (dNTPs) of the four bases of adenine (dATP), cytosine (dCTP), guanine (dGTP), and thymine (dTTP)
- Reverse transcriptase reagent
The combination of RT-PCR and qPCR techniques (sometimes labelled RT-qPCR) is often used in research and clinical labs to analyze gene expression and quantify viral RNA. Since this method uses fluorescence to track the amplification reaction, these kits may also include:
- Fluorogenic primers or labeled fluorogenic probes
- Fluorescent dye
Reagents for cDNA PCR can be purchased separately or as cDNA synthesis kits.
RT-PCR is commonly used for RNA detection, molecular cloning, and gene sequencing. RT-qPCR is used for gene expression analysis, RNAi or microarray validation, pathogen detection, genetic testing, and other disease research.
- (50)
- (6)
- (10)
- (6)
- (1)
- (85)
- (6)
- (3)
- (1)
- (105)
- (23)
- (1)
- (7)
- (5)
- (1)
- (1)
- (2)
- (3)
- (3)
- (13)
- (43)
- (2)
- (3)
- (9)
- (2)
- (1)
- (28)
- (1)
- (1)
- (33)
- (1)
- (13)
- (17)
- (1)
- (50)
- (30)
- (4)
- (1)
- (3)
- (14)
- (12)
- (54)
Filtered Search Results
Applied Biosystems™ TaqMan™ RNA-to-CT™ 1-Step Kit
Delivers consistent RNA target quantification for a wide variety of assays and is validated with Applied Biosystems™ comprehensive library of TaqMan™ Gene Expression assays.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Reverse Transcriptase | ArrayScript™ UP |
| Product Type | One-Step RT-PCR Kit |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | RNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | 1-step RT-qPCR |
| Product Line | RNA-to-CT, TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ AgPath-ID™ One-Step RT-PCR Reagents
AgPath-ID™ One-Step RT-PCR Reagents are designed for sensitive, robust amplification of RNA targets using a rapid single-tube TaqMan™ real-time reverse transcription PCR (RT-PCR) strategy.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 25 X |
| Description | Works on all AB platforms, but is optimized for the 7500. |
| Reverse Transcriptase | ArrayScript™ |
| Concentration | 25X |
| PCR Method | 1-step RT-qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Tube |
| Product Type | One-Step RT-PCR Reagent |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System |
| Sample Type | RNA |
| Reaction Speed | Standard |
| Product Line | AgPath-ID, Ambion |
Thermo Scientific™ SureTect™ Listeria monocytogenes PCR Assay
Rapidly detect Listeria monocytogenes in food and environmental samples with the Thermo Scientific™ SureTect™ Listeria monocytogenes PCR Assay.
Applied Biosystems™ resDNASEQ™ Quantitative HEK293 DNA Kits
The resDNASEQ Quantitative HEK293 DNA Kit is a quantitative PCR (qPCR)-based system for the detection of host-cell DNA from HEK293 cell lines.
| No. of Reactions | 100 Reactions |
|---|---|
| Format | Kit |
| Label or Dye | FAM |
| Quantity | 100 reactions |
| Host Cell | HEK |
| PCR Method | qPCR |
| Product Line | resDNASEQ |
| Detection Method | Primer-probe |
Applied Biosystems™ MycoSEQ™ Mycoplasma Detection Kits
The MycoSEQ Mycoplasma Detection Kit is a real-time mycoplasma PCR assay designed and validated to meet the requirements of European Pharmacopeia Chapter 2.6.7 for use as a nucleic acid amplification technique (NAT).
| Description | Detection for BioProduction process media, cells, raw materials |
|---|---|
| Label or Dye | SYBR Green |
| Quantity | 100 Reactions |
| For Use With (Application) | Mycoplasma Detection |
| Product Line | MycoSEQ |
Applied Biosystems™ resDNASEQ™ Quantitative Sf9 and Baculovirus DNA Kits
The resDNASEQ Quantitative Sf9 and Baculovirus DNA Kit is a duplex quantitative PCR (qPCR)-based system for the detection of residual DNA from the Sf9 baculovirus platform.
| No. of Reactions | 100 Reactions |
|---|---|
| Format | Kit |
| Label or Dye | FAM + VIC |
| Quantity | 100 reactions |
| Host Cell | SF9 + Bacoluvirus |
| PCR Method | qPCR |
| Product Line | resDNASEQ |
| Detection Method | Primer-probe |
Applied Biosystems™ Power SYBR™ Green RNA-to-CT™ 1-Step Kit
The novel formulation reduces false positive results caused by primer dimers, significantly improves data accuracy, and provides reliable detection of low abundance targets.
| Shipping Condition | Wet Ice |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Reverse Transcriptase | ArrayScript™ UP |
| For Use With (Application) | Gene Expression |
| PCR Method | 1-step RT-qPCR |
| Detection Method | SYBR |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | RNA |
| Reaction Speed | Standard |
| Label or Dye | SYBR Green |
| Run Time | Standard |
| Product Line | RNA-to-CT, SYBR |
Applied Biosystems™ MycoSEQ™ Plus Mycoplasma Detection Kits
The MycoSEQ™ Plus Mycoplasma Detection Kit is a TaqMan™-based quantitative PCR (qPCR) kit for the detection of mycoplasma in complex bioproduction samples.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | Medium |
| No. of Reactions | 100 Reactions |
| Product Type | Mycoplasma Detection |
| Form | Liquid |
| Sample Type | Biopharmaceutical Purification Sample, Bulk Drug Substance Sample, Cell Cultures |
| Reaction Speed | Standard |
| Label or Dye | FAM |
| For Use With (Application) | Microbial Detection |
| PCR Method | Multiplex qPCR |
| Target Organism Class | Mollicutes, mycoplasma |
| Product Line | MycoSEQ |
| Detection Method | Primer-probe |
Applied Biosystems™ resDNASEQ™ Quantitative E. coli DNA Kits
This quantitative PCR (qPCR)-based kit, part of the resDNASEQ™ E. coli Residual DNA Quantitation System, enables highly sensitive quantitation of host cell DNA from E. coli expression systems, typically in less than 4 hours.
| No. of Reactions | 100 Reactions |
|---|---|
| Format | Kit |
| Label or Dye | FAM |
| Quantity | 100 reactions |
| Host Cell | E.coli |
| PCR Method | qPCR |
| Product Line | resDNASEQ |
| Detection Method | Primer-probe |
TaqMan™ Advanced miRNA cDNA Synthesis Kit
Kit uses 3' poly-A tailing and 5' ligation of an adaptor sequence to extend the mature miRNAs present in the sample on each end prior to reverse transcription.
Invitrogen™ ROX Reference Dye
ROX Reference Dye is designed to normalize the fluorescent reporter signal in real-time quantitative PCR or RT-PCR.
Applied Biosystems™ TaqMan™ MicroRNA Reverse Transcription Kit
Provides the necessary components for 200 reactions of optimal performance in TaqMan™ MicroRNA Assays.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 10 X |
| Reverse Transcriptase | MultiScribe™ |
| Final Product Type | cDNA |
| Concentration | 10X |
| For Use With (Application) | miRNA analysis |
| PCR Method | 2-step RT-qPCR |
| Detection Method | Primer-probe |
| Size (Final Product) | 200 bp or less |
| Reaction Format | Separate Components |
| Product Type | MicroRNA Reverse Transcription Kit |
| Sample Type | RNA |
| Reaction Speed | Fast |
| Optimal Reaction Temperature | 42°C |
| Product Line | TaqMan |
Applied Biosystems™ resDNASEQ™ Human Residual DNA Quantitation Kits
The resDNASEQ Human Residual DNA Quantitation Kit is a quantitative PCR (qPCR)-based system for the detection of host cell DNA from human cell lines used as expression systems for recombinant proteins.
| No. of Reactions | 100 Reactions |
|---|---|
| Format | Kit |
| Label or Dye | FAM |
| Quantity | 100 reactions |
| Host Cell | Human DNA |
| PCR Method | qPCR |
| Product Line | resDNASEQ |
| Detection Method | Primer-probe |
Invitrogen™ SuperScript™ III Platinum™ One-Step qRT-PCR Kit
Combine the most powerful reverse transcriptase and DNA polymerase technologies to deliver precise and accurate analysis of gene expression in a convenient one-step format.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Taq DNA Polymerase |
| Product Type | One-Step qRT-PCR Kit |
| For Use With (Equipment) | 7500 System, BioRad iCycler iQ, BioRad iQ5, Stratagene Mx4000, MJ Chromo4, MJ Opticon, Stratagene Mx3000P, Stratagene Mx3005P, Cepheid SmartCycler, BioRad MyiQ |
| Sample Type | RNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression,Pathogen Detection,Virus Detection |
| PCR Method | 1-step RT-qPCR |
| Product Line | Platinum, SuperScript |
| Detection Method | Primer-probe |
Applied Biosystems™ QuantStudio™ Absolute Q™ Isolation Buffer
The QuantStudio Absolute Q Isolation Buffer is intended to supplement the materials supplied in the QuantStudio Absolute Q MAP16 Plate Kit.