HPLC Columns
- (1)
- (9)
- (279)
- (600)
- (1)
- (170)
- (3)
- (849)
- (1)
- (61)
- (34)
- (1)
- (8)
- (747)
- (183)
- (46)
- (6)
- (5)
- (1)
- (5)
- (14)
- (631)
- (12)
- (2)
- (1)
- (30)
- (6)
- (17)
- (1)
- (4)
- (21)
- (72)
- (96)
- (325)
- (40)
- (8)
- (8)
- (4)
- (39)
- (39)
- (17)
- (193)
- (10)
- (53)
- (813)
- (2)
- (2)
- (1)
- (50)
- (2)
- (1,787)
- (12)
- (2)
- (63)
- (3)
- (23)
- (6)
- (5)
- (17)
- (6)
- (29)
- (8)
- (1)
- (2)
- (5)
- (14)
- (5)
- (4)
- (3)
- (10)
- (100)
- (2)
- (1)
- (232)
- (1)
- (1)
- (2)
- (3)
- (191)
- (681)
- (1)
- (146)
- (1)
- (2)
- (31)
- (8)
- (83)
- (442)
- (1)
- (105)
- (2)
- (399)
- (28)
- (953)
- (2)
- (2)
- (92)
- (2)
- (2)
- (11)
- (1)
- (20)
- (35)
- (1)
- (21)
- (14)
- (1)
- (1)
- (750)
- (2)
- (2)
- (6)
- (66)
- (1)
- (421)
- (1)
- (460)
- (215)
- (224)
- (107)
- (13)
- (600)
- (5)
- (69)
- (16)
- (5)
- (8)
- (54)
- (87)
- (172)
- (2)
- (14)
- (4)
- (6)
- (16)
- (194)
- (1)
- (10)
- (2)
- (14)
- (104)
- (6)
- (2)
- (11)
- (2)
- (1)
- (9)
- (40)
- (1)
- (125)
- (35)
- (12)
- (187)
- (2)
- (1)
- (2)
- (13)
- (188)
- (48)
- (1)
- (11)
- (122)
- (2)
- (8)
- (2,456)
- (9)
- (21)
- (12)
- (1)
- (10)
- (8)
- (2)
- (96)
- (11)
- (47)
- (13)
- (4)
- (4)
- (4)
Filtered Search Results
Thermo Scientific™ Hypersil™ ODS C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes.
| Pore Size | 120 Å |
|---|---|
| Carbon Load | 10% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ C18 Selectivity HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use these endcapped, ultrapure, silica-based columns to generate exceptional peak shape and resolution for HPLC and LC/MS analyses using generic gradients
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
| Carbon Load | 11% |
|---|---|
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| Surface Area | 170 m²/g |
| USP Type | L1 |
Thermo Scientific™ Hypersil™ ODS-2 C18 Columns
Use as a general purpose C18 phase for acidic and neutral analytes separated under difficult operating conditions.
| Pore Size | 80 Å |
|---|---|
| Carbon Load | 11% |
| Stationary Phase | C18 |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous Type A Silica |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| Product Line | Hypersil Classical |
| USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ aQ C18 Polar Endcapped HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Retain and resolve polar analytes with highly aqueous mobile phases.
| Pore Size | 175 Å |
|---|---|
| Carbon Load | 12% |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Polar |
| Column Type | Reversed Phase |
| pH | 2 to 9 |
| Surface Area | 220 m²/g |
| USP Type | L1 |
Thermo Scientific™ HyPURITY™ ADVANCE™ HPLC Columns, 5μm Particle Size
Use this specialty C8 column for separating compounds showing poor peak shape with traditional alkyl bonded phases.
| Particle Size | 5 μm |
|---|---|
| Carbon Load | 9% |
| Stationary Phase | C8 |
| Phase | Reversed Phase |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| Surface Area | 200 m²/g |
| USP Type | L7 |
Thermo Scientific™ PepMap™ Neo Trap Cartridge
Use the Thermo Scientific™ PepMap™ Neo Trap Cartridge with PepMap™ Neo UHPLC Columns to filter impurities from your peptide mapping samples.
Thermo Scientific™ BioBasic™ PREP SEC 120 Size Exclusion Chromatography HPLC Columns
Achieve outstanding size separation of water soluble compounds with BioBasic™ PREP SEC 120 Size Exclusion Chromatography HPLC Columns.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Diol (OH) |
| Temperature | 60°C |
| Phase | Size Exclusion |
| For Use With | Preparative Size Exclusion |
| Endcapped | No |
| Column Type | Size Exclusion |
| For Use With (Application) | Preparative Chromatography |
| Surface Area | 300 m²/g |
| Max. Pressure | 4300 psi (295 bar) |
| Particle Size | 5 μm |
| Carbon Load | >8.2% |
| Packing Material | Spherical, Fully Porous, Ultrapure Silica |
| Diameter (Metric) | 7.8 mm |
| pH | 2 to 8 |
| USP Type | L59 |
Thermo Scientific™ Hypersil GOLD™ Phenyl HPLC Columns
Use for quick analysis of aromatic analytes, including glucocorticosteroids, estrogens, fat-soluble vitamins, and phospholipids.
| Pore Size | 175 Å |
|---|---|
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Column Type | Reversed Phase |
| pH | 2 to 8 |
| Surface Area | 220 m²/g |
| USP Type | L11 |
Thermo Scientific™ Hypersil™ Phenyl-BDS HPLC Columns
Use as a robust, general-purpose column with aromatic selectivity for QC/QA labs.
| Pore Size | 130 Å |
|---|---|
| Carbon Load | 5% |
| Stationary Phase | Phenyl (Ph) |
| Temperature | 60°C |
| Phase | Reversed Phase |
| Endcapped | Yes |
| Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
| Column Type | Reversed Phase |
| Surface Area | 170 m²/g |
| Max. Pressure | 5800 psi (400 bar) |
| USP Type | L11 |
Thermo Scientific™ ProSwift™ RP-1S PSDVB Reversed Phase HPLC Column, Monolith, 4.6 mm x 50 mm
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Column Format: Analytical Column; Pore Size: Monolith; Column Phase: Reversed Phase
Thermo Scientific™ BetaBasic™ 18 HPLC Columns, 3μm Particle Size
Available in limited dimensions. Please contact Customer Service for more details.
| Pore Size | 150 Å |
|---|---|
| Particle Size | 3 μm |
| Carbon Load | 13% |
| Stationary Phase | C18 |
| Phase | Reversed Phase |
| For Use With | LC/MS, APCI |
| Endcapped | Yes |
| Packing Material | Silica |
| Column Type | Reversed Phase |
| pH | 2 to 12 |
| Surface Area | 200 m²/g |
| USP Type | L1 |
| Column Format | Analytical Column |
Thermo Scientific™ Hypercarb™ Porous Graphitic Carbon HPLC Columns
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Use for enhanced retention of polar compounds and separation of structurally related analytes with stability at pH extremes and high temperature.
Thermo Scientific™ Hypersil™ Silica HPLC Columns
Use the efficient and selective Thermo Scientific™ Hypersil™ Silica LC Columns for normal phase chromatography of nonpolar and moderately polar organic compounds.
| Pore Size | 120 Å |
|---|---|
| Stationary Phase | Silica |
| Temperature | 60°C |
| Phase | Normal Phase |
| Column Type | Normal Phase |
| pH | 2 to 8 |
| Surface Area | 170 m²/g |
| USP Type | L3 |