Filtered Search Results
Cytiva Disposable PD-10 Desalting Columns
Use for desalting and buffer exchange, as well as removal of low-molecular weight compounds. Cytiva Life Sciences™ Disposable PD-10 Desalting Columns provide fast, high-recovery.
Cytiva Whatman™ Qualitative Filter Paper: Grade 1 Circles
Covers a wide range of laboratory applications and is frequently used for clarifying liquids. Whatman™ Qualitative Filter Paper: Grade 1 Circles are widely used standard grade filter papers for routine applications with medium retention and flow rates.
| Thickness (Metric) | 180 μm |
|---|---|
| Flow Rate | 57mL/min. (water) |
| Particle Retention | >11 μm |
| Basis Weight | 87 g/m2 |
| Format | Disc |
| Airflow Rate | 13sec./100mL/sq. in. |
| Grade | Grade 1 |
| Material | Cellulose |
| Porosity | Medium |
| Filtration Speed | 150 sec. |
| For Use With (Application) | A widely used standard grade filter paper for routine applications with medium retention and flow rate. It covers a wide range of laboratory applications and is frequently used for clarifying liquids. |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C
Combines fine particle retention with good flow rate. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/C are ideal for the collection of suspended solids in potable water, natural and industrial wastes.
| Thickness (Metric) | 260 μm |
|---|---|
| Flow Rate | 10.5 sec./100 mL |
| Particle Retention | 1.2 μm |
| Temperature (English) Max. | 932°F |
| Basis Weight | 53 g/m2 |
| Shape | Circle |
| Format | Disc |
| Description | GE’s Whatman filter paper Grade GF/C glass filters offer a good flow rate and loading capacity that support total suspended solids analysis. |
| Thickness (English) | 0.01 in. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/C |
| Material | Borosilicate Glass |
| Waterflow Rate | 105 mL/min |
Cytiva Ficoll-Paque™ PLUS Media
Recognized standard in laboratories worldwide for isolation of human lymphocytes from peripheral blood. Cytiva™ Ficoll-Paque™ PLUS Media maintains the viability and a representative distribution of B and T lymphocytes.
| Content And Storage | 4–30°C |
|---|---|
| Form | Liquid |
| Product Type | Centrifugation Media |
| Color | Colorless to Slightly Yellow |
| Endotoxin Level | < 0.12 EU/mL |
| Shelf Life | 3 years |
| For Use With (Application) | Cell Isolation |
| Sterility | Sterile |
| Density | 1.078 g/mL |
Cytiva Whatman™ Lens Cleaning Tissue
Provides scratch-free cleaning solutions. Whatman™ Lens Cleaning Tissue safely removes surface moisture and grease.
| Description | Won't damage lenses or optical surfaces, leaves no fibers |
|---|---|
| Product Type | Lens Wipe |
| For Use With (Application) | Safe removal of surface moisture and grease. |
Cytiva Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles
Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure. Whatman™ Binder-Free Glass Microfiber Filters GF/F Circles offers an extremely high loading capacity and flow rate.
| Particle Retention | 0.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | Whatman Grade GF/F filter from Cytiva's business is manufactured from pure borosilicate glass. GF/F offers very fine particle retention and good loading capacity and flow rate. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/F |
| Material | Borosilicate Glass |
| For Use With (Application) | Recommended for DNA binding and purification.Very effective in filtering finely precipitated proteins.Can be used in conjunction with GF/D as a prefilter for the successful clarification of extremely ‘difficult’ biochemical solutions and fluids and nucl |
| Thickness (Metric) | 420 μm |
| Flow Rate | 19 sec./100mL/in.2 |
| Type | Filter for TCLP Test Use |
| Format | Disc |
| Thickness (English) | 0.016 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 41 mL/min |
Cytiva Amersham™ ECL™ Prime Western Blotting Detection Reagent
Enables the use of highly diluted primary and secondary antibodies without reducing sensitivity. Cytiva Lifescience™ Amersham™ ECL™ Prime Western Blotting Detection Reagent produces high signal intensity and sensitivity.
| Sensitivity | ∼1 pg |
|---|---|
| Product Type | ECL Western Blot Detection Reagent |
| For Use With (Application) | Sensitive Quantitative or Confirmatory Western Blot |
Cytiva Whatman™ Binder-Free Glass Microfiber Prefiters, Grade GF/D
Functions as a prefilter when used with GF/B microfiber filters. Whatman™ Binder-Free Glass Microfiber Prefilters, Grade GF/D provide efficient membrane protection, especially during liquid scintillation counting.
| Particle Retention | 2.7 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/D fine membrane filters are thick and offer good loading capacity. GF/D can also function as a prefilter when used with GF/B, and it comes in many sizes to fit most filter holders. |
| Temperature (Metric) Max | 500°C |
| Grade | Grade GF/D |
| Material | Borosilicate Glass |
| Thickness (Metric) | 675 μm |
| Flow Rate | 2.6 s/100mL/in2 |
| Type | Prefilter |
| Basis Weight | 121 g/m2 |
| Format | Disc |
| Thickness (English) | 0.02 in. |
| Autoclavable | Autoclavable |
| Waterflow Rate | 681 mL/min |
Cytiva NAP™ Columns, NAP-25
Use for rapid and efficient purification of DNA and oligonucleotides (>10-mer) in less than 15 minutes by gravity flow. Cytiva Life Sciences™ illustra™ NAP™ Columns are disposable columns prepacked with Sephadex™ G-25 DNA Grade
| Includes | Complete step-by-step protocol identifying the fixed volumes needed for equilibration, washing and sample elution |
|---|---|
| Product Type | NAP-25 |
| For Use With (Application) | Rapid and efficient purification of DNA and Oligonucleotides |
Cytiva Whatman™ ReZist Air Venting Filter, 50mm, PTFE, 0.2μm, sterile
Lightweight air venting units suitable for protective vents in-line filtration, and isolation applications when working with chemicallly harsh solvents
Cytiva Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A
Combines high loading capacity with fine particle retention. Whatman™ Binder-Free Glass Microfiber Filters, Grade GF/A are ideal for gravimetric determination of airborne particulates, stack sampling and absorption methods of air pollution monitoring.
| Particle Retention | 1.6 μm |
|---|---|
| Temperature (English) Max. | 932°F |
| Shape | Circle |
| Description | GE’s Whatman Grade GF/A glass microfiber filters feature fine retention. GF/A filters are suitable for water quality parameter measurement and air filtration applications. |
| Temperature (Metric) Max | 500°C |
| Quantity | 100 Pieces |
| Grade | Grade GF/A |
| Material | Borosilicate Glass |
| For Use With (Application) | Used for high-efficiency general purpose laboratory filtration, including water pollution monitoring of effluents, for filtration of water, foodstuff analyses, protein filtration, and radioimmunoassay of weak β emitters. |
| Thickness (Metric) | 260 μm |
| Flow Rate | 13 sec./100mL |
| Type | Fine Retention Filter |
| Format | Disc |
| Thickness (English) | 0.01 in. |
| Waterflow Rate | 143 mL/min |
Cytiva Sera-Mag SpeedBeads™ Carboxyl Magnetic Beads, hydrophobic
Excellent for coupling oligos or proteins directly to the beads. Their cauliflower-like structure gives Sera-Mag beads high binding capacity. The carboxyl groups on these beads can be activated by standard EDC/EDAC chemistry to react with free amino groups, forming amide bonds.
| Content And Storage | 2°C to 8°C |
|---|---|
| Diameter (Metric) | 1 μm |
| Concentration | 5% solids (50mg/mL) |
| For Use With (Application) | DNA Sample Prep,Protein Purification |
Cytiva Whatman™ Quantitative Filter Paper: Grade 40 Circles
Supports accurate analysis in applications sensitive to very low levels of background contamination. Whatman™ Quantitative Filter Paper: Grade 40 Circles are additionally useful in gravimetric analysis where ash content might affect weight measurements of combusted samples.
| Pore Size | 8 μm |
|---|---|
| Particle Retention | 8 μm |
| Airflow Rate | 21 s/100 mL/in2 |
| Quantity | 100 Pk. |
| Grade | Grade 40 |
| Material | Cotton Linters |
| Filtration Speed | ASTM, 75 seconds; Herzberg, 340 seconds |
| For Use With (Application) | Designed for gravimetric analysis and the preparation of samples for instrumental analysis.Gravimetric analysis for numerous components in cements, clays, iron, and steel products.As a primary filter for separating solid matter from aqueous extracts in |
| Thickness (Metric) | 210 μm |
| Flow Rate | Medium |
| Type | Quantitative Filter Paper |
| Format | Disc |
| Filter Type | Ashless |
| Porosity | Medium |