missing translation for 'onlineSavingsMsg'
Learn More
Learn More
Consort™ C3050T Bio-Electronic Analyzer Kit
Description
- Supplied with meter and pH/ORP electrode SP35B, conductivity electrode SK20T, 2 x 50mL buffers (pH 4 and 7), 50mL conductivity standard (0.01 M KCI), 50mL electrolyte (3M KCI), 50mL redox standard (358 mV), flexible electrode holder SH300
- All 3 gold plated BNC connectors each accept different electrodes of which 2 connectors also accept conductivity electrodes
- Multichannel for up to three simultaneous measurements
- Each channel can measure 2 times per second
- No interference between pH/ORP and conductivity electrodes in the same solution
- Custom calibration tables allow the user to add complete buffer/standard-temperature relation tables
- Tables can be entered via a device menu or uploaded from a PC
- Direct rH&sub2; and μW measurement when using a pH, ORP and EC electrode
- Wide display shows all channels at the same time including temperature and date/time
- Stability indicator ensures visualization when the measurement has stabilized
- Stability algorithm ensures stable readings with ability to detect fast changes
- Hold function allows the display to be frozen
- Selectable resolution for more stable readings on mV and pH
- Range lock for conductivity measurements
- Capacitive compensation eliminates the capacitive component of the electrode and cable when measuring low conductivities
- Galvanic isolated USB interface eliminates ground loop effects when connected to a PC
- Pre-programmed standards for pH: 1.68, 2.00, 4.00, 4.01, 6.87, 6.99, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C)
- Pre-programmed standards for conductivity: 1413 μS/cm, 12.88 mS/cm, 111.8 mS/cm (at 25°C)
- Free software and firmware updates downloadable from www.consort.be
Specifications
Specifications
| Accuracy (pH) | 0.01% ±1 digit, 0.1% ±1 digit |
| Accuracy (Conductivity) | 0.5% f.s. of range |
| Accuracy (mV) | 0.01% ±1 digit, 0.1% ± 1 digit |
| Backlight Option | White back-lit |
| Calibration Points (pH) | 1 to 5 |
| Calibration | GLP |
| Calibration Points (Conductivity) | 1 to 3 |
| Channels | Measurement: 3 (conductivity: 2) Temperature: 3 |
| Display Type | LCD, 240 x 64 pixel |
| Range (Conductivity) | 0 to 2000 mS/cm |