Western Blot and Nucleic Acid Membranes and Filter Paper
- (7)
- (16)
- (1)
- (3)
- (12)
- (1)
- (1)
- (3)
- (5)
- (4)
- (3)
- (9)
- (1)
- (1)
- (3)
- (60)
- (9)
- (9)
- (1)
- (12)
- (70)
- (7)
- (1)
- (9)
- (6)
- (13)
- (1)
- (61)
- (9)
- (117)
- (1)
- (1)
- (12)
- (3)
- (1)
- (2)
- (2)
- (1)
- (1)
- (6)
- (1)
- (2)
- (2)
- (2)
- (10)
- (1)
- (3)
- (1)
- (1)
- (26)
- (2)
- (2)
- (1)
- (2)
- (5)
- (2)
- (1)
- (1)
- (15)
- (1)
- (1)
- (26)
- (2)
- (2)
- (2)
- (5)
- (1)
- (4)
- (1)
- (7)
- (15)
- (4)
- (5)
- (1)
- (7)
- (2)
- (1)
- (1)
- (14)
- (1)
- (2)
- (2)
- (3)
- (1)
- (2)
- (1)
- (4)
- (1)
- (3)
- (2)
- (10)
- (3)
- (3)
- (1)
- (30)
- (1)
- (2)
- (2)
- (1)
- (3)
- (1)
- (2)
- (1)
- (2)
- (1)
- (19)
- (3)
- (13)
- (2)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
- (4)
- (3)
- (1)
- (1)
- (2)
- (9)
- (5)
- (5)
- (2)
- (13)
- (1)
- (6)
- (66)
- (110)
- (1)
Filtered Search Results
Thermo Scientific™ PVDF Transfer Membranes, 0.45 μm, 1 Roll
Pierce PVDF Transfer Membranes are made of high-quality polyvinylidene difluoride and provide high binding capacity for proteins and nucleic acids for western, Southern, and northern blotting methods.
Cytiva™ Whatman™ Grade GB003 Blotting Paper
Ensures that no contamination will occur during the transfer steps. Whatman™ Grade GB003 Blotting Paper eliminates sheet to sheet variations with precisely cut membrane sizes.
| Thickness | 0.8 mm |
|---|---|
| Format | Sheet |
| Grade | GB003 |
| Material | Pure Cellulose |
| For Use With (Application) | General purpose paper used as membrane gel support |
Cytiva™ Amersham™ Hybond™ PVDF Membranes: Rolls
Ideal for Western blotting applications where stripping and reprobing are necessary. Cytiva Life Sciences™ Amersham™ Hybond™ PVDF Membranes: Rolls are hydrophobic PVDF membranes.
| Pore Size | 0.2 μm |
|---|---|
| Format | Roll |
Cytiva™ Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls
Use this versatile nitrocellulose membrane for excellent binding affinity for small proteins and peptides, as well as nucleic acids. Cytiva Amersham™ Protran™ NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva™ Amersham™ Hybond™ P 0.45μm PVDF Membrane
Use for chemiluminescent and fluorescent detection methods for proteins of > Mr 20 000. Cytiva Life Sciences™ Amersham™ Hybond™ P 0.45μm PVDF Membrane is a 0.45 μm pore size hydrophobic membrane, with high physical strength, highly suitable for stripping and reprobing.
| Pore Size | 0.45 μm |
|---|
Cytiva™ Whatman™ Gel Blotting Paper Grade GB003
A thick paper ideal for lysis/denaturation of colony or plaque lifts and Western blots
| Grade | GB003 |
|---|---|
| Material | Cellulose |
| For Use With (Application) | Suitable for (lysis/denaturation of colony or plaque lifts and Western blots) |
Thermo Scientific™ Nitrocellulose Membranes, 0.45 μm
Nitrocellulose is a popular binding matrix for western blotting because of its high affinity for proteins and compatibility with a variety of detection methods (western blotting, dot-blot assays, and other protein or nucleic acid methods).
| Shipping Condition | Room Temperature |
|---|---|
| Pore Size | 0.45 μm |
| Material | Nitrocellulose |
Cytiva™ Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls
Use for the best results with fluorescence Western blotting detection applications. Cytiva Life Sciences™ Amersham™ Protran™ Premium NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Material | 100% Pure Nitrocellulose |
| For Use With (Application) | Western blots, dot-blot assays, and other protein or nucleic acid methods |
Cytiva™ Amersham™ Protran™ Supported NC Nitrocellulose Membranes: Rolls
Use for robust protein blotting. Cytiva Life Sciences™ Amersham™ Protran™ Supported NC Nitrocellulose Membranes: Rolls offer excellent sensitivity, resolution, and low background.
| Format | Roll |
|---|---|
| Length (Metric) | 4 m |
| Quantity | Each |
| Material | Nitrocellulose, Inert Polyester |
| Pore Size | 0.2 μm |
|---|
Thermo Scientific™ Owl™ Blotting Paper
Absorb adequate amounts of buffer for semi-dry electroblotting without the loss of mechanical stability with this high-quality blotting paper.
| Flow Rate | 35 mL/min. |
|---|---|
| Format | Sheet |
| For Use With (Equipment) | Owl electroblotting systems |
| Packaging Type | Sheets |
| Material | 100% Cotton Fiber |
| Weight | 183 g/m2 |
| Product Line | Owl |
Merck Immobilon™-E Transfer Membrane
Immobilon™-E provides the a PVDF blotting membrane that wets in transfer buffer or water and eliminates the need for the alcohol pre-wet step.
| Pore Size | 0.45 μm |
|---|---|
| Description | Easily wetted with water |
| Color | White |
| Material | PVDF |
| Code | IEVH |
| Surface | Plain |
| Pore Size | 0.45 μm |
|---|---|
| Material | PVDF |
Cytiva™ Whatman™ Protran™ Nitrocellulose Blotting Membranes: 0.2μm BA83 Protran
100% pure nitrocellulose to ensure the highest binding capacity possible
| Pore Size | 0.2 μm |
|---|---|
| Binding Capacity | High |
| Material | Nitrocellulose |
| For Use With (Application) | Suitable for radioactive, colorimetric, fluorescent, and chemiluminescent detection |
Sartorius™ Nitrocellulose Blotting Membrane
Ideal for Western blotting, DNA blotting as well as dot or slot blots. 0.45 μm nitrocellulose blotting membranes are optimised for all protein blotting systems, such as electrotransfer, semi-dry or simple capillary blotting.