Inline Electrochemistry Analyzers
Instruments and electrodes used to provide ongoing or production-related parameter measurements for water and solutions; sensors or electrodes are incorporated into the inflow or outflow to maintain quality or assess changes in real time.
Filtered Search Results
Products from some of our suppliers do not display in filtered search results. Please
clear all filters
to see these products.
Search Within Results
Keyword Search:
Clear All
1
–
2
of
2
results
Thermo Scientific™ Consumables and Services Kits for Orion™ 2110XP Ammonia Analyzer
Keep needed supplies and service items in stock to avoid lost productivity with Thermo Scientific™ Consumables and Services Kits for Orion™ 2110XP Ammonia Analyzer.
Thermo Scientific™ Orion™ 2110XP Ammonia Analyzer
Control and optimize boiler ammonia levels with continuous, direct and precise ammonia measurements from the Thermo Scientific™ Orion™ 2110XP Ammonia Analyzer.
| Enclosure Rating | Waterproof; IP66; NEMA 4X |
|---|---|
| Width (English) | 17 in. |
| Length (Metric) | 27 cm |
| Response Time | 95% within 2 minutes of injecting a standard solution |
| Length (English) | 11 in. |
| Width (Metric) | 45 cm |
| Channels | 1 |
| Channel1 | Ammonia |
| Sample Streams | 1 |
| Includes | 2110XP ammonia analyzer with Ammonia electrode, reference electrode (100056), ATC probe (2100TP),ammonia calibration standards kit, CD user guide and options kit |
| Channel2 | Optional ph/ORP or Conductivity |
| Flow Rate | 40mL/min. |
| Accuracy | ±15% or 30 ppb, whichever is greater |
| Mounting Options | Wall mount |
| Display Type | Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts |
| Voltage | 85/132 VAC, 170/264 VAC |
| Amperage | 5A |
| Resolution (mV) | 0.1mV |
| Inlet Pressure | 8 to 100psig |
| Certifications/Compliance | CE, CSA, UL, FCC Class A limits |
| Analog Outputs | 2, Galvanically Isolated |
| Case Material | Valox 364 |
| Accuracy (Temperature) | ±0.5°C |
| Relay Details | 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A |
| Height (English) | 26 in. |
| Height (Metric) | 65 cm |
| Communication Details | Modbus with Additional Module |
| Accuracy (mV) | ± (0.5 mV + 0.1%) |
| Keypad Type | Membrane |
| Measurement Ranges | 0 to 10ppm |
| Calibration | Double Known Addition |
| Sample Temperature | 5 to 45°C |
| Current Loops | 2 |
| Alarm Output | 3 |
| Dimensions (L x W x H) | 11 x 17 x 26 in. (27 x 45 x 65cm) |
| Max. Relative Humidity | 5 to 95%, non-condensing |
| Outputs | 0 to 20 mA; 4 to 20 mA |
| Frequency | 0 to 60 Hz |
| Resolution (Temperature) | 0.1°C |
| Range (mV) | ±1999.9m |
| Temperature (Metric) Operating | 5°C to 35°C |
| Sample Inlet | 1/4 in. NPTF tube fitting |